Skip to content
BenchMesh

GW Instek · Multimeter

GW Instek GDM9061 software

Remote control and data logging for the GW Instek GDM9061 multimeter, on Windows, Linux and macOS - with the same panel BenchMesh uses for every multimeter.

Awaiting confirmation

Status

Very likely. Support for the GW Instek GDM9061 was written from GW Instek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real GDM9061 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

Note: 3 A current terminal

What you can do from BenchMesh

Multimeter panel 1 channel

Live readings

  • MEAS
  • MODE
  • OVERLOAD
  • RANGE

Settings you can change

  • Mode
  • Range
  • Rate
  • Temp scale
  • Temp sensor

Connections

USB-serial / RS-232
115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port.
USB-TMC
USB Test & Measurement Class (USB id 2184:0059). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (SCPI socket)
TCP port 3001. Enter the instrument’s IP address.

Notes

  • To confirm on first contactUSB product id 0059 from a libsigrok rule for GDM-9061; GDM-9060 assumed the same.

Sources

The definition was written from these documents (definition gwinstek_gdm9000 v0.1.0).

  • GDM-906X User Manual EN Ver G (2024-03-18), pages 216 RS-232, 224 terminators, 239-246 LAN (TCP port 3001), 246 *IDN?, 274 READ?, 282-285 CONFigure, 294-317 SENSe, 299 NPLC (printed)

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the GW Instek GDM9061?
Very likely. Support for the GW Instek GDM9061 was written from GW Instek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real GDM9061 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the GDM9061 to my PC?
Over USB-serial / RS-232 or USB-TMC or LAN (SCPI socket). 115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port. Then press Detect in BenchMesh: it identifies the multimeter by its reply and adds it to the bench.
What can I control on the GDM9061?
Multimeter: set mode, range, rate, temp scale, temp sensor; read meas, mode, overload, range.
Can I log GDM9061 measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other GDM-906X digital multimeter models