KORAD · Electronic load
KORAD 72-13200 software
Remote control and data logging for the KORAD 72-13200 electronic load, on Windows, Linux and macOS - with the same panel BenchMesh uses for every electronic load.
Status
Very likely. Support for the KORAD 72-13200 was written from KORAD’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real 72-13200 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
Note: Tenma rebrand of the KEL102; identify reply form unknown
What you can do from BenchMesh
Electronic load panel 1 channel
Live readings
- IIN
- INPUT
- MODE
- PIN
- REMOTE
- VIN
Settings you can change
- Curr
- Input
- Mode
- Pow
- Remote
- Remote compensation
- Res
- Volt
Connections
- USB-serial / RS-232
- 115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port.
Notes
- Not supported (yet)LAN is UDP (port 18190): not supported.
Sources
The definition was written from these documents (definition korad_kel10x v0.1.0).
- Korad KEL10x Communication Commands with Computer (8 pp), pages 1-8 (commands 1-30)
- kelctl KEL103-protocol.md (community spec, verified on an RND 320-KEL103), pages FUNC, INP, SYST:LOCK, SYST:COMP, unit suffixes, mode switching
Have one on your bench?
Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.
Questions
- Does BenchMesh work with the KORAD 72-13200?
- Very likely. Support for the KORAD 72-13200 was written from KORAD’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real 72-13200 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
- How do I connect the 72-13200 to my PC?
- Over USB-serial / RS-232. 115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port. Then press Detect in BenchMesh: it identifies the electronic load by its reply and adds it to the bench.
- What can I control on the 72-13200?
- Electronic load: set curr, input, mode, pow, remote, remote compensation, res, volt; read iin, input, mode, pin, remote, vin.
- Can I log 72-13200 measurements to CSV?
- Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
- Is BenchMesh free?
- Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.