RIGOL · Multimeter

RIGOL DM3068 software

Remote control and data logging for the RIGOL DM3068 multimeter, on Windows, Linux and macOS - with the same panel BenchMesh uses for every multimeter.

Awaiting confirmation

Status

Very likely. Support for the RIGOL DM3068 was written from RIGOL’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real DM3068 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

What you can do from BenchMesh

Multimeter panel 1 channel

Live readings

  • MEAS
  • MODE
  • OVERLOAD
  • RANGE

Settings you can change

  • Mode
  • Range
  • Rate

Connections

USB-serial / RS-232
9600 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port.
USB-TMC
USB Test & Measurement Class (USB id 1ab1). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (VXI-11 / LXI)
Discovered through the portmapper, no port to enter. Enter the instrument’s IP address.

Notes

  • To confirm on first contactLAN works through VXI-11 (no raw socket) on DM3058/DM3068: supported since 2026-10-18, not yet confirmed on hardware. DM3058E has no LAN or GPIB.

Sources

The definition was written from these documents (definition rigol_dm3000 v0.1.0).

  • Programming Guide for DM3058/DM3058E (2021-11), pages 2-4..2-5 (*IDN?), 3-14..3-20 (:FUNCtion), 3-29..3-48 (:MEASure), 3-49..3-53 (:RATE)
  • DM3068 Programming Guide (CHM), pages IDN, :FUNCtion?, :MEASure, :MEASure:<fn>, :RATE:VOLTage:DC, Overview (RS-232 commands end \r\n)
  • DM3058 User's Guide, pages RS-232 menu (1200-115200 baud, parity None/Odd/Even); one of GPIB/USB/RS-232 active at a time

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the RIGOL DM3068?
Very likely. Support for the RIGOL DM3068 was written from RIGOL’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real DM3068 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the DM3068 to my PC?
Over USB-serial / RS-232 or USB-TMC or LAN (VXI-11 / LXI). 9600 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port. Then press Detect in BenchMesh: it identifies the multimeter by its reply and adds it to the bench.
What can I control on the DM3068?
Multimeter: set mode, range, rate; read meas, mode, overload, range.
Can I log DM3068 measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other DM3000 series digital multimeter (DM3058/DM3058E/DM3068) models