Skip to content
BenchMesh

RIGOL · Oscilloscope

RIGOL MSO2202A software

Remote control and data logging for the RIGOL MSO2202A oscilloscope, on Windows, Linux and macOS - with the same panel BenchMesh uses for every oscilloscope.

Awaiting confirmation

Status

Very likely. Support for the RIGOL MSO2202A was written from RIGOL’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real MSO2202A yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

What you can do from BenchMesh

Oscilloscope panel 2 channels

Live readings

  • ACQ TYPE
  • BWLIMIT
  • COUPLING
  • DISPLAY
  • FREQ
  • INVERT
  • OFFSET
  • PROBE
  • SCALE
  • SRATE
  • TIMEBASE
  • TIMEOFFSET
  • TRIG LEVEL
  • TRIG SLOPE
  • TRIG SOURCE
  • TRIG STATUS
  • TRIG SWEEP
  • VAVG
  • VPP
  • VRMS

Settings you can change

  • Acquire type
  • Bwlimit
  • Coupling
  • Display
  • Invert
  • Offset
  • Probe
  • Run
  • Scale
  • Timebase
  • Timebase offset
  • Trigger level
  • Trigger slope
  • Trigger source
  • Trigger sweep

Connections

USB-TMC
USB Test & Measurement Class (USB id 1ab1:04b0). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (SCPI socket)
TCP port 5555. Enter the instrument’s IP address.

Sources

The definition was written from these documents (definition rigol_ds2000a v0.1.0).

  • MSO2000A/DS2000A Programming Guide PGA18106-1110 (MSODS2000A_ProgrammingGuide_EN.pdf), pages PDF p4-5 models, p18-19 RUN/STOP/SINGle/AUToscale/CLEar, p22 *IDN?, p28-29 ACQuire, p98-103 CHANnel, p188/218/226/228 MEASure, p291-292 TIMebase, p304-305 and p317-319 TRIGger, p377-390 WAVeform, p394 USB id

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the RIGOL MSO2202A?
Very likely. Support for the RIGOL MSO2202A was written from RIGOL’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real MSO2202A yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the MSO2202A to my PC?
Over USB-TMC or LAN (SCPI socket). USB Test & Measurement Class (USB id 1ab1:04b0). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click. Then press Detect in BenchMesh: it identifies the oscilloscope by its reply and adds it to the bench.
What can I control on the MSO2202A?
Oscilloscope: set acquire type, bwlimit, coupling, display, invert, offset, probe, run; read acq type, bwlimit, coupling, display, freq, invert, offset, probe.
Can I log MSO2202A measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other DS2000A/MSO2000A series digital oscilloscope models