Skip to content
BenchMesh

Siglent · Spectrum analyzer

Siglent SSA3000X / SSA3000X Plus / SSA3000X-R / SVA1000X spectrum analyzer

BenchMesh controls the Siglent SSA3000X / SSA3000X Plus / SSA3000X-R / SVA1000X spectrum analyzer from your PC: live readings on a spectrum analyzer panel, every setting within reach, and every value recordable on one timeline with the rest of your bench.

Models

ModelStatus
SSA3021XAwaiting confirmation
SSA3032XAwaiting confirmation
SSA3015X PlusAwaiting confirmation
SSA3021X PlusAwaiting confirmation
SSA3032X PlusAwaiting confirmation
SSA3050X PlusAwaiting confirmation
SSA3075X PlusAwaiting confirmation
SSA3050X-RAwaiting confirmation
SSA3075X-RAwaiting confirmation
SVA1015XAwaiting confirmation
SVA1032XAwaiting confirmation

What you can do from BenchMesh

Spectrum analyzer panel 1 channel

Live readings

  • ATTEN
  • ATTEN AUTO
  • CENTER
  • DETECTOR
  • MARKER
  • MARKER FREQ
  • MARKER LEVEL
  • POINTS
  • PREAMP
  • RBW
  • RBW AUTO
  • REF LEVEL
  • SCALE
  • SPAN
  • START
  • STOP
  • SWEEP MODE
  • SWEEP TIME
  • TG LEVEL
  • TG OUTPUT
  • TRACE
  • TRACE MODE
  • TRACE UNIT
  • VBW
  • VBW AUTO

Settings you can change

  • Atten auto
  • Attenuation
  • Center
  • Detector
  • Full span
  • Marker
  • Marker freq
  • Peak search
  • Preamp
  • Rbw
  • Rbw auto
  • Ref level
  • Scale
  • Span
  • Start
  • Stop
  • Sweep
  • Sweep time
  • Tg level
  • Tg output
  • Trace mode
  • Vbw
  • Vbw auto

Connections

USB-TMC
USB Test & Measurement Class (USB id f4ec). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (SCPI socket)
TCP port 5025. Enter the instrument’s IP address.

Sources

The definition was written from these documents (definition siglent_ssa3000x v0.1.0).

  • SSA3000X Programming Guide PG0703X_E04A, pages PDF p7 LAN, p14 *IDN?, p21-24 FREQuency, p27 POWer/RLEVel, p31-32 BWIDth, p33-34 TRACe/FORMat, p36 DETector, p38-39 SWEep, p41-49 CALCulate:MARKer, p68-69 TG
  • SSA3000X Plus / SVA1000X Programming Guide PG0703P_E02B, pages printed p13 *IDN?, p29-31 AMPLitude (RLEVel, ATTenuation 0-51 dB, GAIN, PDIVision), p35 SWEep:TIME, p37 INITiate:CONTinuous, p39 BWIDth, p42-44 TRACe:MODE / TRACe:DATA? / FORMat, p45 DETector, p47-53 MARKer, p85 OUTPut / SOURce:POWer (0 to -20 dBm)

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.