Skip to content
BenchMesh

UNI-T · Power supply

UNI-T UDP6722 software

Remote control and data logging for the UNI-T UDP6722 power supply, on Windows, Linux and macOS - with the same panel BenchMesh uses for every power supply.

Awaiting confirmation

Status

Very likely. Support for the UNI-T UDP6722 was written from UNI-T’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real UDP6722 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

Note: Only in the programming manual's *IDN? example (PM p.20); ratings unknown, UDP6720 limits assumed

What you can do from BenchMesh

Power supply panel 1 channel

Live readings

  • CC
  • CV
  • FAIL
  • IOUT
  • OCP
  • OUTPUT
  • OVP
  • POUT
  • REMOTE
  • SBY
  • VOUT

Settings you can change

  • Current
  • Current limit
  • Ocp
  • Output
  • Ovp
  • Remote
  • Voltage
  • Voltage limit

Connections

USB-serial / RS-232
9600 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port.

Sources

The definition was written from these documents (definition unit_udp6700 v0.1.0).

  • UDP6720 Series Programming Manual REV 1.2 (UDP6720_Series_Programming_Manual_V1.2.pdf), pages 2, 7-12, 20 (n / 47 footer)
  • UDP6700 Series Programming Manual (January 30, 2023), pages 1-3 (commands 1-18)
  • UDP6700 Series Data Sheet V1.0, pages Technical Specification

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the UNI-T UDP6722?
Very likely. Support for the UNI-T UDP6722 was written from UNI-T’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real UDP6722 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the UDP6722 to my PC?
Over USB-serial / RS-232. 9600 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port. Then press Detect in BenchMesh: it identifies the power supply by its reply and adds it to the bench.
What can I control on the UDP6722?
Power supply: set current, current limit, ocp, output, ovp, remote, voltage, voltage limit; read cc, cv, fail, iout, ocp, output, ovp, pout.
Can I log UDP6722 measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other UDP6720 series single-output DC power supply (SCPI, RS232) models