UNI-T · Oscilloscope
UNI-T MSO2102CS software
Remote control and data logging for the UNI-T MSO2102CS oscilloscope, on Windows, Linux and macOS - with the same panel BenchMesh uses for every oscilloscope.
Awaiting confirmation
Status
Very likely. Support for the UNI-T MSO2102CS was written from UNI-T’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real MSO2102CS yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
What you can do from BenchMesh
Oscilloscope panel 2 channels
Live readings
- ACQ TYPE
- BWLIMIT
- COUPLING
- DISPLAY
- FREQ
- INVERT
- OFFSET
- PROBE
- SCALE
- TIMEBASE
- TIMEOFFSET
- TRIG LEVEL
- TRIG SLOPE
- TRIG SOURCE
- TRIG STATUS
- TRIG SWEEP
- VAVG
- VPP
- VRMS
Settings you can change
- Acquire type
- Bwlimit
- Coupling
- Display
- Invert
- Offset
- Probe
- Run
- Scale
- Timebase
- Timebase offset
- Trigger level
- Trigger slope
- Trigger source
- Trigger sweep
Connections
- USB-TMC
- USB Test & Measurement Class (USB id 5656). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
- LAN (VXI-11 / LXI)
- Discovered through the portmapper, no port to enter. Enter the instrument’s IP address.
Notes
- To confirm on first contactLAN through VXI-11 (documented via VISA): supported, not yet confirmed on hardware.
Sources
The definition was written from these documents (definition unit_upo2000 v0.1.0).
- MSO/UPO2000 Series Programming Manual V1.0 (MSOUPO2000_Programming_Manual_V1.0.pdf), pages PDF p4 data return (* = invalid), p5 *IDN?, p6 RUN/STOP/AUTO, p14-16 CHANnel, p17-18 TIMebase, p34-37 MEASure, p41-44 TRIGger, p75-76 ACQuire, p79 DISPlay:CLEar, p79-84 WAVeform
Have one on your bench?
Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.
Questions
- Does BenchMesh work with the UNI-T MSO2102CS?
- Very likely. Support for the UNI-T MSO2102CS was written from UNI-T’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real MSO2102CS yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
- How do I connect the MSO2102CS to my PC?
- Over USB-TMC or LAN (VXI-11 / LXI). USB Test & Measurement Class (USB id 5656). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click. Then press Detect in BenchMesh: it identifies the oscilloscope by its reply and adds it to the bench.
- What can I control on the MSO2102CS?
- Oscilloscope: set acquire type, bwlimit, coupling, display, invert, offset, probe, run; read acq type, bwlimit, coupling, display, freq, invert, offset, probe.
- Can I log MSO2102CS measurements to CSV?
- Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
- Is BenchMesh free?
- Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.