GW Instek · Oscilloscope
GW Instek GDS-1072B software
Remote control and data logging for the GW Instek GDS-1072B oscilloscope, on Windows, Linux and macOS - with the same panel BenchMesh uses for every oscilloscope.
Status
Very likely. Support for the GW Instek GDS-1072B was written from GW Instek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real GDS-1072B yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
What you can do from BenchMesh
Oscilloscope panel 2 channels
Live readings
- ACQ TYPE
- BWLIMIT
- COUPLING
- DISPLAY
- FREQ
- INVERT
- OFFSET
- PROBE
- SCALE
- TIMEBASE
- TIMEOFFSET
- TRIG LEVEL
- TRIG SLOPE
- TRIG SOURCE
- TRIG STATUS
- TRIG SWEEP
- VAVG
- VPP
- VRMS
Settings you can change
- Acquire type
- Bwlimit
- Coupling
- Display
- Invert
- Offset
- Probe
- Run
- Scale
- Timebase
- Timebase offset
- Trigger level
- Trigger slope
- Trigger source
- Trigger sweep
Connections
- USB-serial / RS-232
- 115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port.
- LAN (SCPI socket)
- TCP port 3000. Enter the instrument’s IP address.
Notes
- To confirm on first contactThe socket server has no default port in the guide: give host:port when adding it.
Sources
The definition was written from these documents (definition gwinstek_gds1000b v0.1.0).
- GDS-1000B Programming Manual (GDS-1000B_Programming_Manual.pdf); printed page = PDF page, pages p5-7 USB CDC, p8-12 LAN / socket server, p16-17 syntax, p29 *IDN?, p36-41 ACQuire/HEADer, p42 AUTOSet, p43-48 CHANnel, p77-93 MEASure, p112 RUN/STOP/SINGle, p114-115 TIMebase, p119-122 TRIGger, p131-132 TRIGger:STATe?
Have one on your bench?
Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.
Questions
- Does BenchMesh work with the GW Instek GDS-1072B?
- Very likely. Support for the GW Instek GDS-1072B was written from GW Instek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real GDS-1072B yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
- How do I connect the GDS-1072B to my PC?
- Over USB-serial / RS-232 or LAN (SCPI socket). 115200 baud, 8N1. Plug in the USB cable (or a USB-RS-232 adapter); BenchMesh finds the port. Then press Detect in BenchMesh: it identifies the oscilloscope by its reply and adds it to the bench.
- What can I control on the GDS-1072B?
- Oscilloscope: set acquire type, bwlimit, coupling, display, invert, offset, probe, run; read acq type, bwlimit, coupling, display, freq, invert, offset, probe.
- Can I log GDS-1072B measurements to CSV?
- Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
- Is BenchMesh free?
- Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.