Hantek HDM3075 software

Remote control and data logging for the Hantek HDM3075 multimeter, on Windows, Linux and macOS - with the same panel BenchMesh uses for every multimeter.

Awaiting confirmation

Status

Very likely. Support for the Hantek HDM3075 was written from Hantek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real HDM3075 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

Note: LAN (socket 5025) only on the B, H and X variants; S/A variants have USB + RS-232/485 only (UG p.22). RS-232/485 settings undocumented: not offered. GPIB (H) not supported

What you can do from BenchMesh

Multimeter panel 1 channel

Live readings

  • MEAS
  • MODE
  • OVERLOAD
  • RANGE

Settings you can change

  • Mode
  • Range
  • Rate
  • Temp scale
  • Temp sensor

Connections

USB-TMC
USB Test & Measurement Class. No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (SCPI socket)
TCP port 5025. Enter the instrument’s IP address.

Notes

  • Interface on some models onlyLAN only on the B / H / X variants.
  • Not supported (yet)RS-232/485 settings are not documented.

Sources

The definition was written from these documents (definition hantek_hdm3000 v0.1.0).

  • HDM3000 SCPI Programming Reference EN Ver1.03, pages 14-19 (CONFigure, FUNCtion), 23-27 (VOLT/CURR ranges, NPLC), 43 (CAP), 48 (UNIT)
  • HDM3000 User Guide EN Ver2.6, pages 22 (models/interfaces), 95-97 (USB TMC, LAN socket 5025)

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the Hantek HDM3075?
Very likely. Support for the Hantek HDM3075 was written from Hantek’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real HDM3075 yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the HDM3075 to my PC?
Over USB-TMC or LAN (SCPI socket). USB Test & Measurement Class. No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click. Then press Detect in BenchMesh: it identifies the multimeter by its reply and adds it to the bench.
What can I control on the HDM3075?
Multimeter: set mode, range, rate, temp scale, temp sensor; read meas, mode, overload, range.
Can I log HDM3075 measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other HDM3000 series digital multimeter models