Siglent · Multimeter

Siglent SDM3045X software

Remote control and data logging for the Siglent SDM3045X multimeter, on Windows, Linux and macOS - with the same panel BenchMesh uses for every multimeter.

Awaiting confirmation

Status

Very likely. Support for the Siglent SDM3045X was written from Siglent’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real SDM3045X yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.

What you can do from BenchMesh

Multimeter panel 1 channel

Live readings

  • MEAS
  • MODE
  • OVERLOAD
  • RANGE

Settings you can change

  • Mode
  • Range
  • Rate
  • Temp scale
  • Temp sensor

Connections

USB-TMC
USB Test & Measurement Class (USB id f4ec:ee38). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click.
LAN (SCPI socket)
TCP port 5025. Enter the instrument’s IP address.

Notes

  • To confirm on first contactLAN port 5025 confirmed on hardware by a user; Siglent's app note says 5024.

Sources

The definition was written from these documents (definition siglent_sdm3000 v0.1.0).

  • SDM3065X Remote Manual RC06036-E01A, pages 37-48, 54-61, 77-84 (printed)
  • SDM3055 Remote Manual RC06035-E01A, pages 36-47, 60, 83 (printed)
  • SDM3045X Programming Manual, pages 37-48, 61, 83 (printed)

Have one on your bench?

Connect it, press Detect, try the controls - then tell us how it went. Every confirmation moves a model from “Awaiting” to “Community-confirmed” for everyone.

Questions

Does BenchMesh work with the Siglent SDM3045X?
Very likely. Support for the Siglent SDM3045X was written from Siglent’s programming manual and follows the same engine as the bench-tested instruments, but nobody has confirmed it on a real SDM3045X yet. If you own one, connecting it once and reporting the result moves it to Community-confirmed.
How do I connect the SDM3045X to my PC?
Over USB-TMC or LAN (SCPI socket). USB Test & Measurement Class (USB id f4ec:ee38). No vendor driver needed on Linux; on Windows BenchMesh installs Microsoft’s WinUSB driver with one click. Then press Detect in BenchMesh: it identifies the multimeter by its reply and adds it to the bench.
What can I control on the SDM3045X?
Multimeter: set mode, range, rate, temp scale, temp sensor; read meas, mode, overload, range.
Can I log SDM3045X measurements to CSV?
Yes. Right-click any reading to add it to a recording; every instrument on the bench is sampled on one shared timeline and exported as one CSV.
Is BenchMesh free?
Yes. BenchMesh is free and open source, for Windows, Linux and macOS, and works offline.

Other SDM3000 series digital multimeter models